Fybroc's
Optional Flush Assembly Package
The flush assembly* consists of the following
items:
- Shut
off valve and pressure gauge mounted on
epoxy-coated steel bracket. Inlet Site.
- Solenoid
valve and flow meter/metering valve mounted
epoxy-coatel steel bracket. Outlet side.
- Necessary
tubing and fittings to pipe system to
seal gland.
*Note:
The assembly is intended for use on pumps
with double inside mechanical seals (Crane
8-1T, Flowserve RXO).
Consult Factory for additional "special"
configurations.
The system is designed to operate as follows:
- Flush
water is brought to the inlet side of
the system and piped away to a suitable
drain on the outlet side.
- The
normally closed solenoid valve is wired
into the motor starter controls and opens
when the motor is energized.
- The
inlet shut-off valve would remain open
at all times and be used only when the
system needed to be isolated for maintenance
purposes.
- The
flow meter/metering valve would be adjusted
as necessary to obtain a reading of 1/4
- 1/2 GPM.
When
properly installed and operated as referenced
above, the flush system will ensure that
the mechanical seal is operating in the
proper environment and is being cooled and
lubricated as required.
|